Some links to retailers may be affiliate links: if you buy through them we may earn a commission, at no extra cost to you. We have not tested these air conditioners. Capacities and coverage come from the retailer's listings.
What size portable air conditioner do you need?
Portable ACs print a big ASHRAE number on the box and a smaller SACC number in the fine print. The SACC number is the one that matches the sizing chart. Enter your room to get the capacity you need and the portables that really deliver it.
Start from a common room
Your room
Floor area 168 sq ft. The sizing table assumes an 8 ft ceiling.
Sun, people and cooking
Sun on the room
Very sunny: big south- or west-facing windows without shade, or a top floor under the roof.
Each person beyond two adds about 600 BTU of heat.
Air conditioners checked against your room
A unit is the right size when its capacity is between 95% and 150% of what your room needs. Window units are rated by their DOE cooling capacity; portables by their SACC rating, not the bigger number on the box.
LG
LP0625WFR portable AC
Portable
Smallest portable that fits
6,000 BTU SACC · 10,000 on the box single hose Maker says up to 250 sq ftSpecs from the retailer listing · checked Nov 28, 2026
Prices change often, so we link to the retailer's current listing instead of quoting one.
Portable AC ratings: the number on the box and the real capacity
Every portable below is sold with two BTU numbers. The bigger one (ASHRAE) is the one in the product name. The smaller one (SACC) is the U.S. Department of Energy's seasonally adjusted cooling capacity, and it is the one to match against the sizing table.
Ratings from the retailer's listings, checked Nov 28, 2026. Room size is the largest row of the ENERGY STAR table that the SACC rating covers, for an 8 ft ceiling, normal sun and two people.
Portable air conditioner
On the box (ASHRAE)
Real capacity (SACC)
SACC as a share of the box number
Sized for a room
Friedrich ZoneAire ZCP08SA portable AC
8,500 BTU
5,000 BTU
59%
up to 150 sq ft
Aeric AERP051AW portable AC
9,000 BTU
5,500 BTU
61%
up to 150 sq ft
LG LP0625WFR portable AC
10,000 BTU
6,000 BTU
60%
up to 250 sq ft
Frigidaire FHPC102AB1 portable AC
10,000 BTU
6,500 BTU
65%
up to 250 sq ft
Whynter ARC-102CS compact portable AC
10,000 BTU
7,000 BTU
70%
up to 300 sq ft
Whynter ARC-110WD dual hose portable AC
11,000 BTU
7,000 BTU
64%
up to 300 sq ft
Whynter ARC-12SD dual hose portable AC
12,000 BTU
7,500 BTU
63%
up to 300 sq ft
Friedrich ZoneAire ZCP12SA portable AC
13,000 BTU
8,000 BTU
62%
up to 350 sq ft
Whynter ARC-1050XP Wi-Fi portable AC
13,500 BTU
10,000 BTU
74%
up to 450 sq ft
LG LP1025WSSM portable AC
14,000 BTU
10,200 BTU
73%
up to 450 sq ft
Frigidaire 14,000 BTU portable AC
14,000 BTU
10,000 BTU
71%
up to 450 sq ft
Aeric 14,000 BTU portable AC
14,000 BTU
10,000 BTU
71%
up to 450 sq ft
Whynter ARC-147WF dual hose portable AC
14,000 BTU
10,000 BTU
71%
up to 450 sq ft
Keystone 14,000 BTU inverter portable AC
14,000 BTU
12,000 BTU
86%
up to 550 sq ft
Whynter ARC-1230WN NEX inverter portable AC
14,000 BTU
12,000 BTU
86%
up to 550 sq ft
Friedrich ZoneAire 16,000 BTU portable AC with heat pump
16,000 BTU
12,000 BTU
75%
up to 550 sq ft
Why a portable gives less than the number on the box
One hose or two
A single-hose portable cools its own machinery with air from the room and blows that air outside. The room has to replace it, and the replacement is warm air pulled in from outdoors or from the rest of the house. A dual-hose unit brings in outside air through a second hose for that job, so it pulls far less air out of the room.
What SACC measures
The U.S. Department of Energy's test for portable air conditioners covers both single-duct and dual-duct units, and its rating, the seasonally adjusted cooling capacity, counts the heat that comes back through infiltration air and through the warm exhaust hose. The older ASHRAE number on the box does not. That is why two numbers for the same machine can be so far apart.
What the listings show
Across the 16 portables in the table, SACC runs from 59% to 86% of the box number. The 3 inverter models are at 75% to 86%; the rest are at 59% to 74%. The 4 models sold as dual hose run from 63% to 86%, so a second hose alone does not tell you the real capacity. Read the SACC figure.
Source for the test method: 10 CFR Part 430, Subpart B, Appendix CC (U.S. DOE test procedure for portable air conditioners). Shares calculated from the retailer listings, checked Nov 28, 2026.
How the calculator works
Your room: 14 × 12 ft = 168 sq ft. ENERGY STAR table: 6,000 BTU. Total 6,000 BTU, rounded to the nearest 100.
Base size
The ENERGY STAR room air conditioner table, from 5,000 BTU for 100 to 150 sq ft up to 34,000 BTU for 2,000 to 2,500 sq ft. Rooms under 100 sq ft get the smallest size.
Adjustments
Also from ENERGY STAR: −10% for a heavily shaded room, +10% for a very sunny one, +600 BTU for each regular occupant beyond two, +4,000 BTU for a kitchen.
High ceilings
The table assumes 8 ft. For a higher ceiling we scale the floor area by height ÷ 8 before looking it up, because there is more air to cool. That step is our assumption, not part of the ENERGY STAR table.
Portables
We compare a portable's SACC rating with the same number. The "number on the box" estimate assumes SACC is about 70% of the ASHRAE rating, the middle of the 58% to 86% range in the listings we checked; use the SACC figure when the listing gives it.
Right size
95% to 150% of the BTU your room needs. Smaller units run nonstop on hot days; much bigger ones cycle on and off and leave the room clammy.
Questions people ask
Why do portable air conditioners have two BTU ratings?
Since 2017 the U.S. Department of Energy has required portables to show a Seasonally Adjusted Cooling Capacity (SACC), measured in conditions closer to real use, including the heat that leaks back in through the exhaust hose. The older ASHRAE number, often printed bigger on the box, is measured under ideal conditions. In the listings we checked, SACC was 58% to 86% of the ASHRAE number; inverter and dual-hose units keep more of it.
Which number should I compare with the sizing chart?
For a window unit, the BTU on the label. For a portable, the SACC number. The ENERGY STAR chart was written for room air conditioners, and a portable's SACC rating is the closer match. A portable sold as "14,000 BTU" with 10,000 BTU SACC cools about like a 10,000 BTU window unit.
How many BTU do I need for my room?
Start from the floor area. ENERGY STAR's table gives 5,000 BTU for 100 to 150 sq ft, 8,000 BTU for 300 to 350, 10,000 BTU for 400 to 450, 12,000 BTU for 450 to 550 and 14,000 BTU for 550 to 700 sq ft. Then take 10% off for a heavily shaded room, add 10% for a very sunny one, add 600 BTU for each regular occupant beyond two and 4,000 BTU if it is a kitchen.
Window or portable: which cools better?
For the same price, a window unit cools more. It sits outside the room with the hot parts, while a portable keeps the compressor inside and vents through a hose. Portables make sense where a window unit isn't allowed or won't fit, such as casement or sliding windows, rentals or HOA rules.
Is a bigger air conditioner better?
No. ENERGY STAR warns that an oversized unit costs more, wastes energy and does not cool better. It also cools the air before it has time to pull out the moisture, so the room feels cold and clammy. That is why the calculator flags units much bigger than you need.
Model specifications (DOE capacity, SACC and ASHRAE ratings, coverage): retailer listings at Sylvane, checked November 28, 2026.
Results are estimates for a typical room. Very hot climates, poor insulation, lots of electronics or a room open to others can need more. A whole house or rooms over 2,500 sq ft need a different system sized by an HVAC contractor. Last updated November 28, 2026.