Size Planner

Some links to retailers may be affiliate links: if you buy through them we may earn a commission, at no extra cost to you. We have not lab-tested these purifiers. Every number comes from the U.S. ENERGY STAR certified product list, linked on each model.

What size air purifier for wildfire smoke?

Wildfire smoke calls for more cleaning than everyday dust. AHAM's advice is a smoke CADR equal to the floor area, about 7.5 air changes an hour. Enter the room you will shelter in.

Start from a common room

Your room

Most homes: 8 ft. Box ratings assume 8 ft, so a higher ceiling needs more.

Floor area 320 sq ft · air volume 2,560 cu ft. For an L-shaped or open-plan space, add up the parts that share the same air.

What it's for

Cleaning level

Everyday follows the AHAM and ENERGY STAR two-thirds rule. Wildfire smoke follows AHAM's stricter advice.

CADR is measured on the top speed, which is loud. Adding 50% lets the unit keep up on a lower setting, useful in bedrooms.

Models checked against your room

A model covers your room when its certified smoke CADR is at least what you need. The bar shows how many times over; the line marks 1×. Sorted from the smallest that fits.

Brand

The label size is the AHAM suggested room size printed on the box (smoke CADR × 1.55), so you can check a model in a store. Prices change often, so we link to a store's current listing instead of quoting one. Energy use is ENERGY STAR's yearly estimate for running the unit around the clock.

Air purifier size for wildfire smoke, by room size

For smoke, AHAM's guidance is a smoke CADR equal to the room's floor area, which is half again as much as the everyday rule. A purifier sized for dust is undersized when the smoke arrives.

Smoke CADR in cubic feet per minute. Source for the smoke rule: AHAM's wildfire guidance.
Room sizeEveryday rule, 8 ft ceilingWildfire smoke, 8 ft ceilingWildfire smoke, 9 ft ceiling
150 sq ft100 cfm150 cfm169 cfm
200 sq ft134 cfm200 cfm225 cfm
300 sq ft200 cfm300 cfm338 cfm
400 sq ft267 cfm400 cfm450 cfm
500 sq ft334 cfm500 cfm563 cfm
600 sq ft400 cfm600 cfm675 cfm

Using an air purifier when the smoke arrives

Size it for one clean room

The EPA's advice for smoke events is to set up a clean room: a comfortable room that fits everyone, with windows and doors closed and a portable air cleaner running. Size the purifier for that room, not for the house.

Run it on high

During smoke the EPA says to run the air cleaner on its highest fan speed, as often as possible, where people spend the most time, and to change the filter when it looks dirty. This is the opposite of bedroom sizing: plan for the top speed.

Do not add particles indoors

While it is smoky, the EPA advises against frying or broiling, burning candles or incense, using gas or wood stoves, and vacuuming without a HEPA filter.

Mind the air conditioner

A single-hose portable air conditioner can pull smoke into the room, so the EPA says to use one sparingly; with a two-hose unit, seal the window kit tightly. On a window unit, close the outdoor air damper. With central air, a MERV 13 filter, or the highest rating the system can take, and the recirculate setting help.

A box fan filter is a fallback

A furnace filter taped to a box fan does work as a do-it-yourself cleaner, but the EPA generally prefers commercial units with a known CADR. Whatever you use, make sure it does not produce ozone.

Source: U.S. EPA, Wildfires and Indoor Air Quality.

How the calculator works

Your room: 16 × 20 ft floor × 8 ft ceiling = 2,560 cubic feet. For 7.5 air changes an hour: 2,560 × 7.5 ÷ 60 = 320 cfm.

Room volume
Length × width × ceiling height, in cubic feet.
Air changes
How many times an hour the purifier passes the room's whole volume of air through its filter. Everyday: 5, which is what the two-thirds rule gives with an 8 ft ceiling. Pets or allergies: 6. Wildfire smoke: 7.5, from AHAM's advice to match smoke CADR to floor area.
CADR needed
Volume × air changes ÷ 60, because CADR is per minute.
Which CADR
The smoke CADR, because smoke particles are the smallest. We take it from ENERGY STAR's list of certified models, where it is tested to the AHAM standard, instead of the maker's marketing.

Questions people ask

What size air purifier for wildfire smoke?

AHAM recommends a smoke CADR equal to the room's floor area: a 300 sq ft room needs about 300 cfm. That is about 7.5 air changes an hour with an 8 ft ceiling. Close windows, run the purifier on high, and if one unit is not enough, two units' CADRs add up.

What size air purifier do I need for my room?

Measure the floor (length × width) and look for a smoke CADR of at least two-thirds of that number. A 12 × 14 ft bedroom is 168 sq ft, so aim for a smoke CADR of about 112 cfm or more. That is the rule AHAM and ENERGY STAR use, and it works out to five air changes an hour with an 8 ft ceiling. If your ceiling is higher, you need more; the calculator accounts for it.

Do air purifiers remove odors and VOCs?

CADR only measures particles: smoke, dust and pollen. Gases and smells need an activated carbon filter, and a thin carbon sheet does little. If odors or chemicals are your main concern, look for a heavy carbon bed, and treat the CADR here as covering only the particle side.

Are ozone-producing air purifiers safe?

The U.S. EPA advises against air cleaners that produce ozone on purpose. All models we list are ENERGY STAR certified, and we show the ozone each one emitted in testing; most measured 0 or 1 part per billion.

Sources

Results are estimates for particle removal. They are not medical advice. Real performance depends on fan speed, filter age, doors and windows, and where the unit sits. Last updated November 28, 2026.